HGW20HC Linear Guide Block

HGW20HC Linear Guide Block

HGW20HC Heavy-Load Linear Guide Block: 91.4 mm Long, 21.18 kN Dynamic Load on the Same 20 mm Rail A customer building a gantry router came back to us three months after shipping. The axis was fine on paper - the load was well inside the rating - but the blocks on the overhanging side were...
Send Inquiry
Product Introduction

Tianjin OuNaiDa Transmissions Technology Co., Ltd. is one of the leading manufacturers and suppliers of hgw20hc linear guide block in China. If you're going to buy high quality hgw20hc linear guide block, welcome to get more information from our factory. Also, custom service is available.

 

HGW20HC Heavy-Load Linear Guide Block: 91.4 mm Long, 21.18 kN Dynamic Load on the Same 20 mm Rail

A customer building a gantry router came back to us three months after shipping. The axis was fine on paper - the load was well inside the rating - but the blocks on the overhanging side were wearing unevenly and the finish on the far edge of the table had started to drift.

The axial load was never the problem. The moment was.

That is the situation the HGW20HC exists for. It is not a bigger guideway. It is a longer block on exactly the same 20 mm rail, and the only numbers that change meaningfully are the ones that deal with twisting.

What Actually Changes Between CC and HC

Both blocks run on an identical rail. Same 20 mm rail width, same 17.5 mm rail height, same 60 mm bolt pitch, same M5×16 rail mounting bolts, same 2.21 kg/m. If you already have HGW20CC blocks installed, the rail under them will take an HC block without any change to your base machining.

What changes is the block itself.

Parameter HGW20CC HGW20HC Difference
Block mounting length L1 (mm) 50.5 65.2 +14.7
Block overall length L (mm) 76.7 91.4 +14.7
Dimension K1 (mm) 10.25 17.6 +7.35
Basic dynamic load C (kN) 17.75 21.18 +19.3%
Basic static load Co (kN) 27.76 35.90 +29.3%
Static rated moment MR (kN-m) 0.27 0.35 +29.6%
Static rated moment MP (kN-m) 0.20 0.35 +75%
Static rated moment MY (kN-m) 0.20 0.35 +75%
Block weight (kg) 0.40 0.52 +0.12

Dynamic load goes up by about a fifth. Pitch and yaw moment capacity goes up by three quarters. That asymmetry is the whole point of the model, and it is the reason the gantry customer above should have been quoted an HC from the start.

Full Dimension Table

Both blocks, so you can check clearances before committing.

Parameter HGW20CC HGW20HC
Assembly height H (mm) 30 30
H1 (mm) 4.6 4.6
N (mm) 21.5 21.5
Assembly width W (mm) 63 63
Block width B (mm) 53 53
B1 (mm) 5 5
Mounting hole spacing C (mm) 40 40
Block mounting length L1 (mm) 50.5 65.2
Block overall length L (mm) 76.7 91.4
K1 (mm) 10.25 17.6
G (mm) 12 12
Block mounting thread M M6 M6
T (mm) 8 8
T1 (mm) 10 10
H2 (mm) 6 6
H3 (mm) 6 6
Rail width WR (mm) 20 20
Rail height HR (mm) 17.5 17.5
Rail counterbore D (mm) 9.5 9.5
Counterbore depth h (mm) 8.5 8.5
Rail bolt hole d (mm) 6 6
Bolt pitch P (mm) 60 60
End distance E (mm) 20 20
Rail mounting bolt M5×16 M5×16
Rail weight (kg/m) 2.21 2.21

Source: OND ball screw and linear guideway catalogue, HGW series table, p.29. Load values are quoted in the units printed in that table - C and Co in kN, static rated moments in kN-m.

When the Longer Block Earns Its Place

Cantilevered or overhung loads. Anything where the centre of mass sits outside the footprint of the blocks. A tool head on an arm, a rotating fixture, a press ram with the cylinder offset. The pitch moment MP climbing from 0.20 to 0.35 kN-m is the number doing the work here.

Two blocks where you wanted four. Sometimes the carriage simply is not long enough to space four blocks sensibly, and bunching them together defeats the purpose. Two HC blocks at a proper span will usually beat four CC blocks crowded into the same length.

Vertical axes. Gravity plus an offset tool produces a constant yaw moment that never reverses. Constant one-directional loading is harder on a short block than an intermittent load of the same magnitude.

Interrupted cuts and shock. The static rating matters more than the dynamic one when the load arrives as an impact. 35.90 kN against 27.76 kN is meaningful headroom.

Where the HC is wasted: pure axial load, well centred, no overhang. You pay for 14.7 mm of extra carriage length and get 19% more dynamic capacity you did not need.

The Mistakes We See on This Model

Assuming the rail needs upgrading too. It does not. Same rail, same bolts, same pitch. People quote an HGW25 when an HGW20HC would have solved it, and then have to re-machine the base for a 23 mm rail.

Forgetting the 14.7 mm. The block is longer at both the L and L1 dimension. If your carriage plate already has the four M6 holes drilled on a 40 mm × 53 mm pattern, those holes still work - the mounting pattern is unchanged. But the block body now extends further, and we have seen it foul an end stop or a cable carrier bracket that was sized around a CC.

Mixing CC and HC on the same rail. Mechanically they will both run. But they have different block lengths and different stiffness, so load sharing between them is uneven and the shorter one wears first. Use one type per axis.

Reading the moment figures as interchangeable. On the CC, MP and MY (0.20) are lower than MR (0.27). On the HC all three are 0.35. If you sized an axis on MR alone and the real load case is pitch, the CC gives you less margin than you assumed.

Mounting Notes That Apply to Both

THK's published guidance for profiled rail is worth following regardless of whose rail you buy. Remove burrs, dents and dust from the mounting surface first - THK states: "Be sure to remove burr, dent and dust from the mounting surface of the machine to which the LM Guide is to be mounted before installing the LM Guide."

Rail bolts get tightened with a torque wrench, working outward from the middle: "To achieve stable accuracy when tightening the LM rail mounting bolts, tighten them in order from the center to the rail ends."

And check the holes line up before you apply any force. THK is explicit that "Forcibly tightening the bolt into a displaced hole may deteriorate the accuracy."

For the block-to-carriage bolts, tighten in diagonal order rather than around the perimeter - THK recommends this "to evenly secure the table."

The torque figures themselves depend on what your base is made of, which is a bigger deal than most people expect. We covered the full table in our note on rail bolt torque.

Ordering

Specify block type, number of blocks per rail, rail length, and whether you need blocks and rails matched as a set. For long axes assembled from jointed rail sections, say so when you order - the rails have to be manufactured and marked as a matched run, and that cannot be fixed afterwards.

If you are unsure whether your load case is axial or moment-dominated, send us the carriage geometry: block spacing, where the load acts, and how far it sits from the rail centreline. That is usually enough to tell you whether the CC is fine or the HC is worth the extra length.

Related: EGH20SA low-profile block where height is the constraint rather than moment capacity, and preload selection if you are still deciding on preload class.

Tianjin OuNaiDa Transmissions Technology Co., Ltd. manufactures linear guideways, ball screws, support units, gears, racks, sprockets and couplings. Established 2008, CE and ISO 9001:2015.

Hot Tags: hgw20hc linear guide block, China hgw20hc linear guide block manufacturers, suppliers, factory, gear value, linear guideway advanced design, linear guideway bearings, linear guideway rails, linear guideway replacement, linear motion systems

Send Inquiry

whatsapp

Phone

VK

Inquiry